Coleman Hot Tub Error Codes

admin

Coleman Spa Owners Manuals The Spa Works. We are a wholesale distributor of spa and hot tub parts. We sell exclusively to pool spa professionals. Error Codes Spa. Depot. Spaside Readout. Modern hot tubs with electronic controls feature spaside keypads with digital readouts. Wondering what your spa is trying to tell you  Below is a list of common error codes from the top manufacturers of control equipment for hot tubs. Height=450&odnWidth=450&odnBg=FFFFFF' alt='Coleman Lazy Spa Error Codes' title='Coleman Lazy Spa Error Codes' />Disclaimer Although we hope this information will be useful, error codes are subject to change without notice. We make no representation as to the accuracy or completeness of this data and are not responsible for errors or omissions. Refer to your owners manual. ACC Applied Computer ControlsCo. Ld Temperature in the spa heater housing is below 4. F. Status of the heater element is unknown. The low speed pump or circ pump will operate continuously until the temperature rises above 4. P6OVXVqO_Y/hqdefault.jpg' alt='Coleman Hot Tub Troubleshooting' title='Coleman Hot Tub Troubleshooting' />LF Low Flow Heater Dry Error Codes. Sometimes solids. Spa hot tub trouble codes OH, OHH, HH, OHS. HOT These are Overheating error codes, and the spa goes into cool down mode. Basic hot tub flow error causes and. I have a belize 3000L hot tub my error codes is LOC and FLC at the same time. I did have a flo code as well but put in a. Coleman Spa Manuals, Spa Parts for All Spa Brands, Spa Jets, Spa Troubleshooting. Coleman Spa ManualF. OH Over heat. The spa is at a temperature above 1. Do not use spa when temperature is flashing or the OH message is displayed. HLo. H Hi Limit Over Heat. Hi limit sensor is disconnected or shorted or the spa temperature is above 1. F. SEo. P Sensor open or disconnected. Heater disabled but the spa is operational. SESH Sensor short, nonfunctional. Heater disabled but the spa is operational. PSo. C Pressure switch open with circulating pump. PSo. L Pressure switch open with low pump. PSo. H Pressure switch open with high pump. To. E Time out error. Rare system error. Spa unusable. Contact ACC. Balboa used by Belize Spas and many other hot tubspd Power supply, unit running on battery backup. OH Sensors reading 1. F. OHH Overheat. Spa has shut down. One sensor has detected 1. F at heater. OHS Overheat. Spa has shut down. One sensor has detected 1. F. Flo Improper flow or pressure switch malfunction. Cool Water temp 2. ICE Potential freeze condition has been detected. Sn. 1 Hi limit sensor malfunction. Sn. 3 Temp sensor malfunction. Sn. A Spa is shut down. Sensor plugged into jack A is not working. Snb Spa is shut down. Sensor plugged into jack B is not working. Sn. S Sensors out of balance. If alternating with temp, may be temporary condition. If display shows only this message blinking spa is shut down. HFL Substantial difference between temperature sensors detected. Could indicate a flow problem. LF Persistent low flow problems. Displays on the 5th occurrence of HFL message with 2. Heater is shut down, but other spa functions run normally. Inadequate water detected in heater. Inadequate water detected in heater. Displays on third occurrence of dr message. Spa is shut down. Pr When spa is first actuated, it will go into Priming Mode. ILOC Interlock failure possible pump or ozone spike. Unknown water temperature. Displays when first powered up after refill. Std Spa operating in Standard Mode. Ecn Spa operating in Economy Mode. SE Spa operating in Standard in Economy Mode. Brett Aqualine. OH Temp exceeds 1. FFr Freeze condition temp below 4. FFL Pressure switch failure. EO Shorted temp sensor. E1 Open temp sensor. E2 Shorted hi limit sensor. E3 Open hi limit sensor. E4 Shorted flow switch. E7 Improper electrical connection. CTIth. 13. 9 On startup indicates temperature probe problem. On startup indicates temperature probe problem. On startup indicates water temperature less than 3. F. OH Overheating, water over 1. F. System will restart when temp. Overheating, water over 1. F. System will restart when temp. HL High limit switch tripped. Dream Maker Hot Tubs. OH Overheat 1. 08 F, spa is deactivated. Do not enter the water. FL Flow. Pressure switch is not working. SN Non functional high temperature sensor. Heater is deactivated. F2 4 hours daily filtration. F4 8 hours daily filtration. F6 1. 2 hours daily filtration. FC continuous filtration. Easy. Pak. C Celsius. CL Current Time of Day. ECdu Economy Mode Duration. Econ Economy Mode Turn On. F Fahrenheit. Fldu Filter Cycle Duration. Flon Filter Cycle Turn On. FLC Pressure Switch Alarm. FLO Pressure Switch Alarm. Fr. EE Freeze Protection Alarm. HL High Temperature Alarm. Loc Panel Keypad Locked. Pr. H Temperature Sensors Alarm. Guns Girls Lawyers Spies Set Up Events. Prr Temperature Sensors Alarm. Tu Temperature Set Celsius. Tu Temperature Set Fahrenheit. Gecko. FLO Pressure switch failure, switch open. FLC Pressure switch failure, switch closed. Prr Temp sensor failure. Prh Hi limit sensor failure. HL Sensor measuring 1. FFr. E Possible freeze condition detected. Hercules. OH Spa temp exceeds acceptable limits. FLO Flow problem. ICE Freeze condition detected. SN1 Hi limit sensor failure. SN2 Temp sensor failure. Hurricane. PS Flow or pressure switch failure. SH Shorted sensor. OP Open Sensor. LO Temp below 6. F freeze. HL Temp above 1. FHydro Quip. C Celsius. CL Current Time of Day. ECdu Economy Mode Duration. Econ Economy Mode Turn On. F Fahrenheit. Fldu Filter Cycle Duration. Flon Filter Cycle Turn On. FLC Pressure Switch Alarm. FLO Pressure Switch Alarm. Fr. EE Freeze Protection Alarm. HL High Temperature Alarm. Loc Panel Keypad Locked. Pr. H Temperature Sensors Alarm. Prr Temperature Sensors Alarm. Tu Temperature Set Celsius. Tu Temperature Set Fahrenheit. Jacuzzi Whirlpool. OH Overheat Protection Heater is deactivated, pumps low speed is activated. COOL Spa water is more than 2. F cooler than the temperature set point. FLO Flow Switch heater is deactivated. Pump may also be deactivated. Hold Panel sensors have been pressed too many times in a short period of time. HOT Circuit Board temperature has exceeded acceptable limit. ICE Freeze protection. No action is necessary. I CE2   Freeze protection. No action is necessary. Pn. L Communication between the panel and circuit board is faulty. Watchdog spa is deactivated A problem has been detected. Sn. 1 Open sensor heater is deactivated or  Shorted sensor spa is deactivated. Sn. 3 Open or shorted sensor heater disabled. FLO2 Closed or shorted flow switch on system startup. Pinnacle. OH Temperature has exceeded 1. FSN Sensor failure. FL Flowpressure switch stuck in closed position. Spa Builders. Sn. Nonfunctional high temperature sensor. Heater is deactivated. Sn. 2 Nonfunctional temperature sensor. Heater is deactivated. FL1 Water flow problem, inhibited or pressure switch malfunction. Check for proper spa water level and ensure pump is primed. Check for clogged filter. FL2 Pressure switch problem. Switch closed while pump is deactivated. COL Cool condition. If water temperature drops 2.